MP 100
Odour Problem
Unpleasant lingering odours can leave some rooms unusable or create a negative impression which affects your company image and customer feedback. Attempting to mask odours with fragrances can make the area even more unpleasant.
Many odours are created from microorganisms, musty odours can indicate mould whereas unpleasant stale odours may be a warning sign of high levels of bacteria. Traditional cleaning and disinfecting will not eliminate odours, you cannot clean the air itself and even simple odours from food, illness or smoke can remain in an area for days if untreated. Methods such as fogging can increase damp issues or leave chemical residues, often meaning areas cannot be occupied for several hours.
The MP100 unit offers a rapid, mobile solution to odour issues, with many odours cleared in minutes.
HEALTHCARE PROBLEMS
– Embarrassing odours
– Infections from bacteria, viruses, mould and fungi
– Masking agents
– Recycled air
BENEFITS OF USING AIRSTERIL MP100
> Rapidly clear embarrassing odours from smoke, food, illness, incontinence, damp and mould
> Perfect for a wide variety of unoccupied areas
> Hotels – bedrooms, conference rooms
> Offices – meeting rooms, break room, cafeteria
> Healthcare – communal areas, smoking rooms
> Gyms – studios, changing areas, washrooms
PERFECT FOR USE IN
– Ambulance deep cleaning
– Ward decontamination
– Care home bedrooms (not suitable for use in occupied areas)
– Food preparation areas
Guideline Treatment Times To Clear | 20m2 |
Body Odour / Stale Air | 15 minutes |
Mild smoke odours / food odours | 30 minutes |
Sickness odours / incontinence odours | 1 hour |
Strong persistent odours* | 4 hours+ |
*Odours engrained in fabrics/furnishing will require longer or repeated treatments to clear. Contact us for a specific guide.
HOW AIRSTERIL TECHNOLOGY WORKS
A combination of technologies working together:
Internal
– Germicidal Irradiation by dual UV light (Ultraviolet) kills microorganisms (bacteria, viruses and mould) by disrupting their DNA and removing their reproductive capabilities.
– PCO – Photocatalytic Oxidation, UV reacts with our Catalyst (Ti02) to form highly reactive but short lived oxidising Hydroxyl Radicals (OH) which break down Volatile Organic Compounds (VOCs).
– Interaction of the Dual waveband UV with the TiO2 heterogeneous catalyst both creates and breaks down Oxygen molecules transforming Oxygen into a highly reactive states of Ozone and Superoxide Ions which leave the unit as “Plasma Quatro”.
Transmitted Technology
– The negatively charged Superoxide Ions charge airborne contaminates causing them to cluster together and fall from the air as they become too heavy, aiding all other processes. This can remove airborne particulates down to 0.0001 micron, that’s better than any HEPA filter.
– Targeted Ozone produced via the specialist lamp gets the hardest to the hardest to reach areas breaking down contamination in the air and on exposed surfaces. Ozone damages the cell wall of microorganisms stopping reproduction and destroying the cell.
HOW OUR MULTIPURPOSE SYSTEM WORKS
All AIRsteril units utilise our unique combination of 5 technologies. They eliminate unpleasant odours and control harmful bacteria and viruses 24 hours a day, 365 days of the year. The MP100 is designed for rapid odour clearance and microbial reduction. Its portable design, allows quick re-location to resolve odour issues around the building, or just to quickly freshen each room as part of the cleaning cycle.
Due to its high power each room should be unoccupied during treatment as it would be unpleasant to remain in the area. Once treatment is over the unit should be switched off unit and allow natural ventilation for 15-20 minutes to ensure the environment is now pleasant to occupy and all odours are eliminated. Units should be mounted as high as practical for best operation, the higher the unit, the faster odours will be cleared.
OPERATION AND SAFETY
The unique balance of technology used by AIRsteril has been tried, tested and refined over many years to ensure the best achievable results with every unit is supplied.
– Due to the unit design UV light cannot escape the unit from any angle meaning it is completely safe. – Ozone levels used are substantially below the most stringent emissions regulations worldwide – Power via a plug with an inline switch allows flexible installation and easy connection to existing sockets
DEMONSTRATION OF HOW AIRSTERIL TECHNOLOGY WORKS AND
OUTPERFORMS OTHER PRODUCTS ON THE MARKET.
SCIENTIFICALLY PROVEN PRODUCTS MADE BY SPECIALISTS IN AIR PURIFICATION
See how our technology outperforms the competition and trusted by world leaders as seen in cop26 (world climate change conference 2021).
AIRsteril technology is proven to clear 99.9% of airborne germs within 10 minutes. We have over 10 years of proven testing with professional laboratories both in the UK and internationally, AIRsteril is the name you can trust.
The air around us contains microorganisms, bacteria, viruses, moulds, fungi and volatile organic compounds. Airborne microorganisms can create offensive odours, spread infections and be responsible for the continued growth of mould.
Microorganisms are deposited on surfaces from the air where they continue to grow, magnifying odour issues and the risk of infections. Standard room cleaning and disinfecting procedures can only offer a temporary solution. As soon as an area is cleaned the airborne microorganisms immediately begin to settle, recolonizing the surfaces and increasing the odour and infection problems. Many places still only use fragrances which attempt to mask odours and do not target the source; the contamination both in the air and on surfaces.
AIRsteril technology changes all of this…
TECHNICAL DETAILS
MP RANGE DIMENSIONS //
750mm (l) x 130mm (w) x 100mm (d)
POWER SUPPLY //
220-230V 38 watts
SET UP //
Usually free standing as high as possible for maximum dispersal and quickest effect. Can also be wall or ceiling mounted if required.
CONSTRUCTION //
Anodised aluminium, solid extrusion
WEIGHT //
3.4kg
OPERATION //
As required for odour clearance, or continuous use for areas over 100m2 . Requires annual lamp change.
SERVICING AND MAINTENANCE
Power must be disconnected before attempting any servicing and only undertaken by a competent individual. All AIRsteril partners have fully trained engineers to carry out all servicing work. The MP cover is easily removed by taking out four screws from the cover, then the two finger screws removed from the lamp housing plate to allow lamp replacement. Any dust or debris build up should be cleared from the interior. Lamps must be changed on an annual basis to maintain performance.
Reviews